Network Management
ROSA™ EM - Element Management System
Description
The ROSA™ Element Manager (EM) is specifically designed
to cost effectively monitor and control the transmission
network of headends, hub sites and HFC outside plants, and
transmitter sites. This unit manages the equipment that is co-
located on the site where the ROSA EM resides, whether this
equipment has an SNMP, serial (RS-232/422/485) or contact
closure interface.
The main functions of the ROSA EM are to:
•
•
•
•
•
Monitor the health of the transmission network
Act as an SNMP proxy
Send alarm notifications when a problem occurs
Automatically backup failed devices
Perform local automation tasks
The ROSA EM supports several hundred Scientific-Atlanta and third-party devices. Support for new devices is
continuously being added to the ROSA EM, which can be exported to existing installations with a simple software
upgrade.
The ROSA EM actively polls all of the devices that it manages looking for problems and in the event a problem is
detected, ROSA EM will send alarm notifications to the appropriate personnel via SNMP trap, Email, Pager or
SMS. ROSA EM communicates with the managed devices via their proprietary protocols or contact closures then
translates this information to SNMP, which can be passed to a higher level network management system. When
ROSA EM is configured to perform backup protection it will automatically initiate pre-defined backup schemes that
reroutes signals, activates and configures standby devices all within seconds of a device failure.
The ROSA EM is a 2 RU high, 19-inch rack-mount embedded platform that operates without a monitor or
keyboard. The operator interfaces with the ROSA EM via a simple easy-to-use and understand Web browser
client. Communication to the ROSA EM can be established over any LAN/WAN network that supports Ethernet.
In addition, dial-in and dial-out (e.g., ISDN) is supported for cases where only a switched connection is available.
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Cost-effective solution for management of devices in all locations (large headend to small hubs/OTN)
Manages Scientific-Atlanta and third-party equipment via proprietary protocol, SNMP, or contact closures
Translates proprietary protocols to SNMP and passes configuration/alarm information to network managers
Highly reliable (no fans, no hard drive) hardware and software solution
Alarm notification with Email, Pager or SMS
Easy to use, intuitive Web browser interface
Provides easy integration with multiple client options – Web browser, TNCS, ROSA NMS, 3rd Party NMS
Open standards based interfaces (SNMP, HTTP, FTP, HMS, DateTime, etc.)
Delivered with software already installed
Software can be upgraded remotely over LAN/WAN
Automatic remote backup and restore to save the entire configuration of the ROSA EM
Seamless integration into currently installed TNCS and ROSA systems
Dual temperature probes available as option
2 RU, 19-inch rack-mount chassis
ROSA EM - Element Management System
Specifications
Remote Control and Configuration Ports (*)
Ethernet management port
Number of ports
2
Connector type
RJ-45
Physical layer
LED indication
Dielectric isolation
10/100Base-T
LINE and ACT
1.5 kV AC
Note: In case a client (simple Web browser, TNCS client,
ROSA NMS client or third party NMS) is used in combination
with ROSA EM, it must be possible to perform a successful
ping command between ROSA EM and the client in both
directions.
RS-232 Serial Ports
Number of ports
4
Connector type
Pin layout
Male, 9 pin Sub-D
Standard DTE
Physical layer
RS-232
Baud rate
Protocol
ESD
Up to 38.4 kbaud
RCDS, SMC or other
Max. 15 kV Performance Criterion B
RS-232 - RS-485 - RS-422 Serial Ports (configurable)
Number of ports
Connector type
Pin layout
4
Male, 9 pin Sub-D
Configurable (for RCDS or SMC pin layout refer to user’s
guide)
Physical layer
Baud rate
RS-232, RS-422 or RS-485
Up to 38.4 kbaud
Protocol
RCDS, SMC or other
ESD
Max. 15 kV Performance Criterion B
Digital Input Ports
Number of ports
108
Connector type
Female, 25 pin Sub-D
Contacts per port
Decision threshold
Input voltage range
ESD
2
TTL / CMOS
Max. ± 15 V
Max. 15 kV Performance Criterion B
Galvanic Isolated Digital Input Ports
Number of ports
12
Connector type
Female, 25 pin Sub-D
2
Low: < 0.8 V, High: > 2 V
Max. ± 15 V
Max. 60 V DC or 42 V AC
Max. 15 kV Performance Criterion B
500 V port to port
Contacts per port
Decision threshold
Differential over voltage protection
Common mode input voltage
ESD
Dielectric isolation
Relay Outputs
Number of ports
24
Connector type
Female, 25 pin Sub-D
3 (common, normal open, normal closed)
42 V AC / 60 V DC
1 A @ 30 V DC
500 V
Resistive load
Contacts per port
Maximum voltage
Maximum load current
Dielectric isolation
Load
External Temperature Sensor
Number of ports
2
Note: Temperature sensors available as an option.
3
ROSA EM - Element Management System
Specifications - continued
Remote Control and Configuration Ports - continued
Analog Inputs
Number of ports
Connector type
Contacts per port
Input range
8
Female, 25 pin Sub-D
2
0 to +15 V by default, configurable to 0 to +60 V
Type
Differential input
Resolution
8 bit (55 mV step with 15 V input range, 250 mV step with
60 V input range)
Input impedance
> 100 kΩ
Analog Outputs
Number of ports
Connector type
Contacts per port
Output voltage range
Resolution
2
Female, 25 pin Sub-D
2
0 to +10 V
8 bit (40 mV step)
1 kΩ
Output impedance
Craft Interface
Number of ports
Connector type
Pin layout
1
Male, 9 pin Sub-D
Standard DTE
Physical layer
Baud rate
ESD
RS-232
Up to 38.4 kbaud (default 19.2 kbaud)
Max. 15 kV
Keyboard and Mouse
Number of ports
Connector type
Pin layout
2
PS/2
Standard PS/2
RS-232
Max. 15 kV
Physical layer
ESD
Monitor
Number of ports
Connector type
Pin layout
1
DB15H
VGA
Resolution
Up to 1024 x 768 (SVGA)
(*) Note concerning Safety Extra-Low Voltage (SELV) Circuit Warning
To avoid electric shock and in order to comply with the product’s regulatory safety compliance certifications:
• Do not connect any I/O, signal or communication port to circuits falling beyond the requirements for SELV circuits
• Always verify voltage, current and energy levels of connected circuits against SELV requirements (for a full definition of SELV
requirements, refer to UL, EN or IEC 60950 standards for limit values).
• Ensure that only ‘Digital Input Ports’, Galvanic Isolated Digital Input Ports’ or ‘Relay Outputs’ are connected to outdoor circuits.
Important:
• SELV voltage limits for indoor connections are < 60 V DC (or peak) or < 42.4 V AC RMS.
• SELV voltage limits for outdoor connections are lower than those for indoor connections.
• Outdoor voltages should be no greater than 15 Vrms, 21.2 Vpk, and 30 V DC under normal operating conditions.
• Cabling of outdoor circuits must be shorter than 140 feet or 42 meters.
• In all cases it is needed to protect outdoor cabling by means of a Primary Surge Protector at the position where the wiring enters the
building.
• Outdoor cabling should be routed away and spaced with adequate clearances from power and lighting conductors.
• For installations in the United States, refer to the appropriate sections in the National Electrical Code (NEC).
• For installations in other countries, ensure that the installation complies with the National requirements taking in account the above-
mentioned recommendations.
4
ROSA EM - Element Management System
Specifications - continued
Management Specifications
Number of managed devices depends on license with an absolute maximum of 1000 devices
Maximum number of simultaneously connected web browser sessions is 12
Maximum number of simultaneously connected TNCS clients is 8
Environmental Specifications
Within specs
+10°C to +45°C / +50°F to +113°F
0°C to +50°C / +32°F to +122°F
-20°C to +70°C / -4°F to +158°F
Operating temperature
Storage temperature
Power Supply AC
Nominal voltage range
100 – 240 V AC
Full voltage range
Ripple & Noise
Maximum power consumption
90 – 264 V AC, 47 - 63 Hz
Compliant with ETSI ETS 300-132-1
25 W
Power Supply DC
Nominal voltage
-48 V DC
Ripple & Noise
Maximum power consumption
Compliant with ETSI ETS 300-132-2
25 W
Mechanical Specifications
Height
Width
Depth
Weight
88 mm / 3.48 in. (2 RU)
482 mm / 19 in.
470 mm / 18.5 in.
Approx. 5 kg / 11.02 lbs
5
ROSA EM - Element Management System
Ordering Information
Part Number
ROSA EM – North and Latin America
ROSA EM AC version
ROSA EM, 100 - 240 V AC US, DCL Class 1 (0-10 devices)
ROSA EM, 100 - 240 V AC US, DCL Class 2 (0-25 devices)
ROSA EM, 100 - 240 V AC US, DCL Class 3 (0-50 devices)
ROSA EM, 100 - 240 V AC US, DCL Class 4 (0-100 devices)
ROSA EM, 100 - 240 V AC US, DCL Class 5 (0-250 devices)
ROSA EM, 100 - 240 V AC US, DCL Class 6 (0-500 devices)
ROSA EM, 100 - 240 V AC US, DCL Class 7 (0-750 devices)
ROSA EM, 100 - 240 V AC US, DCL Class 8 (0-1000 devices)
4005326
4005370
4005371
4005372
4005373
4005374
4005375
4005376
ROSA EM DC version
ROSA EM, -48 V DC US, DCL Class 1 (0-10 devices)
ROSA EM, -48 V DC US, DCL Class 2 (0-25 devices)
ROSA EM, -48 V DC US, DCL Class 3 (0-50 devices)
ROSA EM, -48 V DC US, DCL Class 4 (0-100 devices)
ROSA EM, -48 V DC US, DCL Class 5 (0-250 devices)
ROSA EM, -48 V DC US, DCL Class 6 (0-500 devices)
ROSA EM, -48 V DC US, DCL Class 7 (0-750 devices)
ROSA EM, -48 V DC US, DCL Class 8 (0-1000 devices)
4006322
4007210
4007211
4007212
4007213
4007214
4007215
4007216
Part Number
ROSA EM – EMEA (Europe, Middle-East, Africa) and AP (Asia, Pacific)
ROSA EM Headend
ROSA EM Headend, 100 - 240 V AC EU DCL Class 5 (0-250 headend devices)
ROSA EM Headend, 100 - 240 V AC UK DCL Class 5 (0-250 headend devices)
ROSA EM Headend, 100 - 240 V AC AUS DCL Class 5 (0-250 headend devices)
ROSA EM Headend, -48 V DC DCL Class 5 (0-250 headend devices)
4005317
4005320
4005323
4007217
ROSA EM Hub & HFC
ROSA EM Hub & HFC, 100 – 240 V AC EU DCL Class 6 (0-500 Hub & HFC network devices)
ROSA EM Hub & HFC, 100 – 240 V AC UK DCL Class 6 (0-500 Hub & HFC network devices)
ROSA EM Hub & HFC, 100 – 240 V AC AUS DCL Class 6 (0-500 Hub & HFC network devices)
ROSA EM Hub & HFC, -48 V DC DCL Class 6 (0-500 Hub & HFC network devices)
4005318
4005321
4005324
4007218
ROSA EM Transmitter sites
ROSA EM Tx Site, 100 – 240 V AC EU DCL Class 1 (0-10 devices in transmitter sites)
ROSA EM Tx Site, 100 – 240 V AC UK DCL Class 1 (0-10 devices in transmitter sites)
ROSA EM Tx Site, 100 – 240 V AC AUS DCL Class 1 (0-10 devices in transmitter sites)
ROSA EM Tx Site, -48 V DC DCL Class 1 (0-10 devices in transmitter sites)
4005319
4005322
4005325
4007219
Part Number
ROSA EM Upgrades
ROSA EM Device Count License (DCL) Upgrade
Class Info
4005377
DCL Class 1 : 0-10 devices
DCL Class 2 : 0-25 devices
DCL Class 3 : 0-50 devices
DCL Class 4 : 0-100 devices
DCL Class 5 : 0-250 devices
DCL Class 6 : 0-500 devices
DCL Class 7 : 0-750 devices
DCL Class 8 : 0-1000 devices
Part Number
ROSA EM Options
ROSA EM external temperature sensor, maximum 2 per ROSA EM
(cable length 15 m / 50 ft)
4005382
6
ROSA EM - Element Management System
Ordering Information - continued
Related Products
Cable Kits
For Scientific-Atlanta TNCS devices and RCDS devices, refer to the corresponding cable kits.
Part Number
ROSA Network Management System
Components for ROSA Network Management System
Performance Logging Task
V9529450
V9529652
7001733
Performance Data Compression Task
Service Availability Reporting
SNMP Manager Runtime License (runs custom SNMP profile drivers)
SNMP Profile Manager (includes one SNMP Manager Runtime license)
Group-wise Equipment Manager
V9529615
V9529616
V9529823
V9529595
V9529610
UDD Runtime License (runs custom Universal Device Drivers)
UDD Profile Manager (includes one UDD Runtime license)
Note: Reporting Component is part of the basic ROSA package
Copernicus MKIV ROSA Network Management Server
COPERNICUS ROSA Network Management Server 100-120/200-240 V AC Std
Standard SQL database (MSDE)
Including RS-232/4 and RS-485/4, ROSA 3.X Client, license for 250 points
COPERNICUS ROSA Network Management Server 100-120/200-240 V AC LS
Large System SQL database (MS SQL Server 2000 Standard Edition)
Including RS-232/4 and RS-485/4, ROSA 3.X Client, license for 250 points
V000112011
V000112021
Part Number
TNCS Client
Software
TNCS Software, Version 2.0
4006663
738693
Desktop Computer (Optional)
Computer, Server, Mini-tower, Includes: 17" Monitor, Speakers, Keyboard, CD Writer, Ethernet Card,
56KModem, Windows 2000
Rack Mount Computer (Optional)
Computer, Server, Rack Mount, Includes: Ethernet Card, Internal 56K Modem, CD Writer, RS-458/422
PCI Card and Windows 2000 (4 RU)
735727
Rack Mount Keyboard & 17" Monitor (Optional)
Keyboard, Rack Mount, with Touchpad and Mounting Hardware (1 RU)
Monitor Cabinet, Rack Mount, for 17" monitor, (11 RU)
Monitor, 17" with Internal Speakers
730165
735741
738034
Rack Mount Keyboard & Flip-up Monitor (Optional)
Keyboard, Rack Mount, with Flip-up Monitor, Touchpad, & Mounting Hardware (2 RU)
735740
747746
Power Cord
Power Cord, European
Scientific-Atlanta and the Scientific-Atlanta logo are registered trademarks of Scientific-Atlanta, Inc.
ROSA and Copernicus are trademarks of Scientific-Atlanta Europe NV.
Specifications and product availability are subject to change without notice.
© 2004 Scientific-Atlanta, Inc. All rights reserved.
Part Number 7003710 Rev F
September 2004
7
|