TM
RuggedSwitch RSG2100
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports
TM
eRSTP
ZPL
Zero-Packet-Loss™
TM
The RuggedSwitch™ RSG2100 is an industrially hardened,
fully managed, modular, Ethernet switch specifically designed
to operate reliably in electrically harsh and climatically
demanding utility substation and industrial environments.
The RSG2100's superior ruggedized hardware design
coupled with the embedded Rugged Operating System
(ROS™) provides improved system reliability and advanced
cyber security and networking features making it ideally
suited for creating secure Ethernet networks for mission-
critical, real-time, control applications.
RuggedRated for Reliability in Harsh Environments
ꢀ.Immunity to EMI and heavy electrical surges
ꢁ
.
Zero-Packet-Loss™ Technology
ꢁ
.
Meets IEEE 1613 Class 2 (electric utility substations)
Exceeds IEC 61850-3 (electric utility substations)
Exceeds IEC 61800-3 (variable speed drive systems)
Exceeds IEC 61000-6-2 (generic industrial)
Exceeds NEMA TS-2 (traffic control equipment)
ꢁ
.
ꢁ
.
ꢁ
.
ꢁ
.
ꢀ.-40 to +85°C operating temperature (no fans)
ꢀ.Conformal coated printed circuit boards (optional)
ꢀ.18 AWG galvanized steel enclosure
The RSG2100's modular flexibility offers 10BaseFL /100BaseFX
/1000BaseX fiber and 10/100/1000BaseTX copper port
combinations. Optional front or rear mount connectors make the
RSG2100 highly versatile for any application and can support
multiple fiber connectors (ST, MTRJ, LC, SC) without loss of port
density. The RSG2100 is packaged in a rugged galvanized steel
enclosure with industrial grade DIN, panel, or 19" rack-mount
mounting options.
ꢀ.Hazardous Location Certification: Class 1 Division 2
TM
Rugged Operating System (ROS ) Features
ꢀ.Simple plug and play operation - automatic learning,
negotiation, and crossover detection
ꢀ.RSTP (802.1w) and Enhanced Rapid Spanning
Tree (eRSTP™) network fault recovery (<5ms)
ꢀ.Quality of Service (802.1p) for real-time traffic
ꢀ.VLAN (802.1q) with double tagging and GVRP support
ꢀ.Link aggregation (802.3ad)
Features and Benefits
ꢀ.IGMP Snooping for multicast filtering
Ethernet Ports
ꢀ.Port Rate Limiting and Broadcast Storm Limiting
ꢀ.Port configuration, status, statistics, mirroring, security
ꢀ.Loss of link management on fiber ports
ꢀ.up to 3-Gigabit Ethernet ports
ꢀ.up to 16-Fast Ethernet ports
-
copper and/or fiber
-
copper and/or fiber
ꢀ.2 port modules for tremendous flexibility
ꢀ.Non-blocking, store and forward switching
ꢀ.Supports many types of fiber (Multimode, singlemode,
bi-directional single strand)
ꢀ.Long haul optics allow Gigabit distances up to 70km
ꢀ.Multiple connector types (ST, MTRJ, LC, SC)
ꢀ.SNTP time synchronization (client and server)
ꢀ.Industrial automation features (eg. Modbus)
Management Tools
ꢀ.Web-based, Telnet, CLI management interfaces
ꢀ.SNMP v1/v2/v3
ꢀ.Remote Monitoring (RMON)
Cyber Security Features
ꢀ.Multi-level user passwords
ꢀ.SSH/SSL encryption
ꢀ.Enable/disable ports, MAC based port security
ꢀ.Port based network access control (802.1x)
ꢀ.VLAN (802.1q ) to segregate and secure network traffic
ꢀ.Radius centralized password management
ꢀ.SNMPv3 encrypted authentication and access security
ꢀ.Rich set of diagnostics with logging and alarms
Universal Power Supply Options
ꢀ.Fully integrated, dual-redundant (optional) power supplies
ꢀ.Universal high voltage range: 88-300VDC or 85-264VAC
ꢀ.Popular low voltage ranges: 24VDC(9-36VDC),
48VDC (36-72VDC)
ꢀ.Screw or pluggable terminal blocks available
ꢀ.Terminal blocks for reliable
maintenance free connections
ꢀ.CSA/UL 60950 safety approved
I
I
S
SRUGGEDCOM
9001:20000
9001:2 00
O
O
to +85°C
CERTIFIED
RuggedSwitchTM RSG2100
1
TM
RuggedSwitch RSG2100
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports
TM
ROS Features
A configurable "weighted fair queuing" algorithm
Cyber Security
Cyber security is an urgent issue in many industries where
advanced automation and communications networks play
a crucial role in mission critical applications and where high
reliability is of paramount importance. Key ROS™ features that
address security issues at the local area network level include:
controls how frames are emptied from the
queues.
VLAN (IEEE 802.1q)
Virtual local area networks (VLAN) allow the segregation
of a physical network into separate logical networks with
independent broadcast domains. A measure of security is
provided since hosts can only access other hosts on the
same VLAN and traffic storms are isolated. ROS™ supports
802.1q tagged Ethernet frames and VLAN trunks. Port
based classification allows legacy devices to be assigned
to the correct VLAN. GVRP support is also provided to
simplify the configuration of the switches on the VLAN.
ꢀ.Passwords - Multi-level user passwords secures switch
against unauthorized configuration
ꢀ.SSH / SSL - Extends capability of password protection
to add encryption of passwords and data as they cross
the network
ꢀ.Enable / Disable Ports - Capability to disable ports so that
traffic can not pass
ꢀ.802.1q VLAN - Provides the ability to logically segregate
traffic between predefined ports on switches
ꢀ.MAC Based Port Security - The ability to secure ports on
a switch so only specific Devices / MAC addresses can
communicate via that port
ꢀ.802.1x Port Based Network Access Control - The ability
to lock down ports on a switch so that only authorized
clients can communicate via this port
Link Aggregation (802.3ad)
The link aggregation feature provides the ability to aggregate
several Ethernet ports into one logical link (port trunk) with
higher bandwidth. This provides an inexpensive way to set up
a high speed backbone to improve network bandwidth. This
feature is also known as "port trunking", "port bundling", "port
teaming", and "ethernet trunk".
ꢀ.Radius - Provides centralized password management
ꢀ.SNMPv3 - encrypted authentication and access security
IGMP Snooping
ROS uses IGMP snooping (Internet Group Management
Protocol v1&v2) to intelligently forward or filter multicast traffic
streams (e.g. MPEG video) to or from hosts on the network.
The ROS™ cyber security features are included to help
address the various industry specific security standards such
as NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005 This reduces the load on network trunks and prevents
and PCSRF SPP-ICS.
packets from being received on hosts that are not involved.
ROS™ has a very powerful implementation of
IGMP snooping that:
Enhanced Rapid Spanning Tree Protocol (eRSTP™)
RuggedCom eRSTP allows the creation of fault-tolerant ring
and mesh Ethernet networks that incorporate redundant links
that are 'pruned' to prevent loops. eRSTP yields worst-case
ꢀ.Can be enabled on a per VLAN basis.
ꢀ.Detects and filters all multicast streams regardless of
whether subscribers exist.
1
fault recovery of 5ms times the 'bridge diameter' and allows
rings of up to 80 switches. For example, a ring of ten
switches will have fault recovery times under 50ms. eRSTP
implements both STP and RSTP to ensure interoperability
with commercial switches unlike other proprietary 'ring'
solutions.
ꢀ.Supports "router-less" operation by supporting an
"active" mode.
ꢀ.Restores traffic streams immediately after an RSTP
topology change.
SNMP (Simple Network Management Protocol)
SNMP provides a standardized method for network
management stations the ability to interrogate devices from
different vendors. SNMP versions supported by ROS™ are
v1, v2c, and v3. SNMPv3 in particular provides security
features (such as authentication, privacy, and access control)
not present in earlier SNMP versions. ROS™ also supports
numerous standard MIBs (Management Information Base)
allowing for easy integration with any network management
system (NMS).
Quality of Service (IEEE 802.1p)
Some networking applications such as real-time control
or VoIP (voice over IP) require predictable arrival times for
Ethernet frames. Switches can introduce latency in times
of heavy network traffic due to the internal queues that buffer
frames and then transmit on a first come first serve basis.
ROS™ supports 'Class of Service' in accordance with IEEE
802.1p that allows time critical traffic to jump ahead to the
front of the queue thus minimizing latency and reducing jitter
to allow such demanding applications to operate correctly.
ROS™ allows priority classification by port, tags, MAC
address, and IP type of service (TOS).
1
eRSTP fault recovery times may be approximated as follows:
For 100 Mbps, fault recovery performance is <5ms/hop
For 1,000 Mbps, fault recovery performance is <5ms/hop + 20ms
RuggedSwitchTM RSG2100
3
TM
RuggedSwitch RSG2100
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports
TM
ROS Features
SNMP (Simple Network Management Protocol) (cont’d)
Port Configuration and Status
A feature of SNMP supported by ROS™ is the ability to
generate "traps" upon system events. A NMS can record
traps from multiple devices providing a powerful network
ROS™ allows individual ports to be 'hard' configured for
speed, duplex, auto-negotiation, flow control and more. This
allows proper connection with devices that do not negotiate or
have unusual settings. Detailed status of ports with alarm and
SNMP trap on link problems aid greatly in system
troubleshooting.
TM
troubleshooting tool. RuggedVue is RuggedCom's NMS
that provides graphical visualization of the network and is
fully integrated with all RuggedCom products.
SNTP (Simple Network Time Protocol)
Port Statistics and RMON (Remote Monitoring)
ROS™ provides continuously updating statistics per port
that provide both ingress and egress packet and byte
counters as well as detailed error figures. Also provided
is full support for the RMON statistics, history, alarms, and
event groups. RMON allows for very sophisticated data
collection, analysis and detection of traffic patterns.
SNTP automatically synchronizes the internal clock of all
ROS™ devices on the network. This allows for correlation
of time stamped events for troubleshooting.
SCADA and Industrial Automation
ROS™ contains features that optimize network performance
and simplify switch management based on the unique
requirements found in SCADA and industrial automation
applications. Features such as Modbus TCP management for
retrieval of switch data using the ubiquitous Modbus protocol
and DHCP Option 82, a Rockwell Automation ODVA
requirement for IP address assignment based on the location
of the end device, provide capabilities not found in typical
"commercial" or "office grade" Ethernet switches.
Event Logging and Alarms
ROS™ records all significant events to a non-volatile
system log allowing forensic troubleshooting. Events
include link failure and recovery, unauthorized access,
broadcast storm detection, and self-test diagnostics
among others. Alarms provide a snapshot of recent
events that have yet to be acknowledged by the network
administrator. An external hardware relay is de-energized
during the presence of critical alarms allowing an
external controller to react if desired.
Port Based Network Access Control (802.1x)
ROS™ supports the IEEE 802.1x standard that defines
a mechanism for port-based network access control which
provides a means of authenticating and authorizing
devices attached to LAN ports.
HTML Web Browser and Telnet User Interfaces
ROS™ provides a simple, intuitive user interface for
configuration and monitoring via a standard graphical
web browser or via Telnet. All system parameters include
detailed on-line help to make setup a breeze. ROS™ ,
presents a common look and feel and standardized
configuration process allowing easy migration to other
RuggedCom managed products.
Port Rate Limiting
ROS™ supports configurable rate limiting per port to limit
unicast and multicast traffic. This can be essential to
managing precious network bandwidth for service providers.
It also provides edge security for denial of service
(DOS) attacks.
Configuration via ASCII Text File
Broadcast Storm Filtering
All configuration parameters are stored in an ASCII
formatted text file that can easily be transferred via TFTP
or Xmodem. The configuration file can be saved for
backup purposes and easily manipulated by a text editor.
The same text file can be downloaded to the switch at
a later date in order to re-configure or restore
a previous configuration.
Broadcast storms wreak havoc on a network and can cause
attached devices to malfunction. This could be disastrous on
a network with mission critical equipment. ROS™ limits this
by filtering broadcast frames with a user-defined threshold.
Loss of Link Management
Some intelligent electronic devices (IEDs) have dual fiber
optic ports with automatic failover to a backup port should the
primary fail. ROS™ ensures this mechanism works reliably
under all failure modes by appropriately disabling link signals
when required. ROS™ also flushes learned MAC addresses
to ensure the failover occurs quickly.
Command Line Interface (CLI)
A command line interface can be used in conjunction
with remote shell to automate data retrieval, configuration
updates, and firmware upgrades. A powerful SQL-like
capability allows expert users the ability to selectively
retrieve or manipulate any parameters the device
has to offer.
Port Mirroring
ROS™ can be configured to duplicate all traffic on one port
to a designated mirror port. When combined with a network
analyzer, this can be a powerful troubleshooting tool.
RuggedSwitchTM RSG2100
4
TM
RuggedSwitch RSG2100
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports
EMI and Environmental Type Tests
IEC 61850-3 EMI TYPE TESTS
TEST
Description
Test Levels
Severity Levels
Enclosure Contact
Enclosure Air
Enclosure ports
+/- 8kV
+/- 15kV
20 V/m
4
4
x
IEC 61000-4-2
IEC 61000-4-3
ESD
Radiated RFI
Signal ports
+/- 4kV @ 2.5kHz
+/- 4kV
x
4
4
4
D.C. Power ports
A.C. Power ports
IEC 61000-4-4
Burst (Fast Transient)
+/- 4kV
3
+/- 4kV
Earth ground ports
Signal ports
D.C. Power ports
A.C. Power ports
+/- 4kV line-to-earth, +/- 2kV line-to-line
+/- 2kV line-to-earth, +/- 1kV line-to-line
+/- 4kV line-to-earth, +/- 2kV line-to-line
4
3
4
IEC 61000-4-5
IEC 61000-4-6
Surge
Signal ports
10V
10V
10V
3
3
3
D.C Power ports
A.C. Power ports
Induced (Conducted) RFI
3
10V
3
Earth ground ports
Enclosure ports
IEC 61000-4-8
IEC 61000-4-29
Magnetic Field
40 A/m continuous, 1000 A/m for 1 s
30% for 0.1s, 60% for 0.1s, 100% for 0.05s
N/A
N/A
D.C. Power ports
Voltage Dips & Interrupts
30% for 1 period, 60% for 50 periods
N/A
N/A
A.C. Power ports
2
IEC 61000-4-11
IEC 61000-4-12
100% for 5 periods, 100% for 50 periods
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
30V Continuous, 300V for 1s
30V Continuous, 300V for 1s
10%
2kVac (Fail-Safe Relay output)
2kVac
2kVac
5kV (Fail-Safe Relay output)
5kV
5kV
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
D.C. Power ports
D.C. Power ports
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
D.C. Power ports
A.C. Power ports
3
3
3
4
4
Damped Oscillatory
IEC 61000-4-16
IEC 61000-4-17
Mains Frequency Voltage
Ripple on D.C. Power Supply
3
N/A
N/A
N/A
N/A
N/A
N/A
IEC 60255-5
IEC 60255-5
Dielectric Strength
H.V. Impulse
IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS
Test
Description
Test Levels
Severity Levels
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
D.C. Power ports
A.C. Power ports
Earth ground ports3
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
D.C. Power ports
A.C. Power ports
+/- 8kV
+/- 15kV
35 V/m
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
IEEE C37.90.3
IEEE C37.90.2
ESD
Radiated RFI
IEEE C37.90.1
IEEE C37.90.1
Fast Transient
Oscillatory
+/- 4kV
2.5kV common mode @1MHz
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
5kV (Fail-Safe Relay output)
5kV
5kV
2kVac
2kVac
2kVac
IEEE C37.90
IEEE C37.90
H.V. Impulse
Dielectric Strength
Environmental Type Tests
Description
Test
IEC 60068-2-1
IEC 60068-2-2
Test Levels
-40°C, 16 Hours
+85°C, 16 Hours
Severity Levels
Cold Temperature
Dry Heat
Test Ad
Test Bd
N/A
N/A
95% (non-condensing), 55°C , 6
cycles
IEC 60068-2-30
Humidity (Damp Heat, Cyclic)
Test Db
N/A
IEC 60255-21-1
IEC 60255-21-2
Vibration
Shock
Tests Fc
Tests Ea
2g @ (10 - 150) Hz
30g @ 11mS
Class 2
Class 2
Notes:
1. Only applicable to functional earth connections separated from the safety earth connection.
2. Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high,
( e.g. shipboard application and for severe transportation conditions")
RuggedSwitchTM RSG2100
5
TM
RuggedSwitch RSG2100
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports
Technical Specifications
EMI Immunity and Environmental Compliance
ꢀ.IEC 61000-6-2 Industrial (Generic)
Power Supply
ꢀ.Power Consumption: 28W Max
ꢀ.24VDC: 9-36 VDC, 1.2A
ꢀ.IEC 61800-3 Industrial (Variable Speed Drive Systems)
ꢀ.IEC 61850-3 Electric Utility Substations
ꢀ.IEEE 1613 Electric Utility Substations
ꢀ.48VDC: 36-72 VDC, 0.6A
ꢀ.HI Voltage AC/DC: 88-300VDC or 85-264VAC
ꢀ.NEMA TS 2 Traffic Control Equipment
Critical Alarm Relay
ꢀ.Form-C contact ratings:
Max Voltage 250VAC,125VDC
IEEE Compliance
ꢀ.802.3-10BaseT
ꢀ.802.3u-100BaseTX, 100BaseFX
ꢀ.802.3x-Flow Control
ꢀ.802.3z-1000BaseLX
ꢀ.802.3ab-1000BaseTX
ꢀ.802.3ad-Link Aggregation
ꢀ.802.1d-MAC Bridges
ꢀ.802.1d-Spanning Tree Protocol
ꢀ.802.1p-Class of Service
ꢀ.802.1q-VLAN Tagging
Max Current 2A@250VAC, 0.15A @125VDC,
2A@30VDC
Physical
ꢀ.Height: 4.42cm / 1.74"
ꢀ.Width: 46.48cm / 18.3"
ꢀ.Depth: 31.5cm / 12.4"
ꢀ.Weight: 5.2kg / 11.5 lbs
ꢀ.Ingress Protection: IP40 (1mm objects)
ꢀ.Enclosure: 18 AWG galvanized steel enclosure
ꢀ.Mounting: DIN rail or panel mounted
ꢀ.802.1w-Rapid Spanning Tree Protocol
ꢀ.802.1x-Port Based Network Access Control
IETF RFC Compliance
ꢀ.RFC768-UDP
Switch Properties
ꢀ.Switching method: Store & Forward
ꢀ.Switching latency: 7 us
ꢀ.Switching bandwidth: 9.2 Gbps
ꢀ.MAC addresses: 8192
ꢀ.MAC address table size: 64kbytes
ꢀ.Priority Queues: 4
ꢀ.RFC783-TFTP
ꢀ.RFC791-IP
ꢀ.RFC792-ICMP
ꢀ.RFC793-TCP
ꢀ.RFC826-ARP
ꢀ.RFC854-Telnet
ꢀ.Frame buffer memory: 2 Mbit
ꢀ.VLANs: 4094
ꢀ.IGMP multicast groups: 256
ꢀ.Port rate limiting
ꢀ.No head of line blocking
ꢀ.RFC894-IP over Ethernet
ꢀ.RFC1112-IGMP v1
ꢀ.RFC1519-CIDR
ꢀ.RFC1541-DHCP (client)
ꢀ.RFC2030-SNTP
ꢀ.RFC2068-HTTP
ꢀ.RFC2236-IGMP v2
ꢀ.RFC2284-EAP
ꢀ.RFC2475-Differentiated Services
ꢀ.RFC2865-Radius
ꢀ.RFC3414-SNMPv3-USM
ꢀ.RFC3415-SNMPv3-VACM
Approvals
ꢀ.ISO: Designed and manufactured using a ISO9001: 2000
certified quality program
ꢀ.CE Marking
ꢀ.Emissions: FCC Part 15 (Class A),
EN55022 (CISPR22 Class A)
ꢀ.Safety: cCSAus (Compliant with CSA C22.2 No. 60950, UL
60950, EN60950)
ꢀ.Laser Eye Safety (FDA/CDRH): Complies with 21
CFR Chapter1, Subchapter J.
IETF SNMP MIBS
ꢀ.RFC1493-BRIDGE-MIB
ꢀ.RFC1907-SNMPv2-MIB
ꢀ.RFC2012-TCP-MIB
Warranty
ꢀ.RFC2013-UDP-MIB
ꢀ.5 Years - Applicable to design and manufacturing
related product defects.
ꢀ.RFC2578-SNMPv2-SMI
ꢀ.RFC2579-SNMPv2-TC
ꢀ.RFC2819-RMON-MIB
Network Management
ꢀ.HTTP graphical web-based
ꢀ.SNMP v1, v2c, v3
ꢀ.Telnet, VT100
ꢀ.Command Line Interface (CLI)
ꢀ.RFC2863-IF-MIB
ꢀ.draft-ietf-bridge-rstpmib-03-BRIDGE-MIB
ꢀ.draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB
ꢀ.IANAifType-MIB
RuggedSwitchTM RSG2100
6
TM
RuggedSwitch RSG2100
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports
Dimensions
RuggedSwitchTM RSG2100
7
TM
RuggedSwitch RSG2100
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports
Mounting Options
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 9
Slot 10
RuggedSwitchTM RSG2100
8
TM
RuggedSwitch RSG2100
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports
Order Codes
RSG2100 -______ -______ -____ -____ -____ -____ -____ -____ -____ -____ -____ -____ -____ -_____
Main
Mount PS1
PS2
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 9
S5: Gigabit Ethernet Modules for slot 5
Slot 10
ꢀ
.
XXXX = Empty
ꢀ
.
CG01 = 2 x 10/100/1000Tx RJ45
ꢀ
.
FG01 = 2 x 1000SX - Multimode, 850nm, LC, 500m
Main: Ethernet and Power Connectors
ꢀ
.
ꢀ
.
FG02 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 10km
R = Ethernet on rear; LED panel on front; power connector on rear
F = Ethernet on front; LED panel on front; power connector on rear
B = Ethernet on rear; LED panel on top; power connector on rear
T = Ethernet on front; LED panel on top; power connector on rear
ꢀ
.
ꢀ
.
FG03 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 10km
ꢀ
.
ꢀ
.
FG04 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 25km
ꢀ
.
ꢀ
.
FG05 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 25km
ꢀ
.
FG50 = 2 x 1000LX SFP - Blank (no optical transceiver)
ꢀ
.
FG51 = 2 x 1000SX SFP - Multimode, 850nm, LC, 500m
Mount: Mounting Options
RM = 19" Rack Mount Kit
DP = DIN and Panel Mount Kit
RD = 19" Rack, DIN, and Panel Mount Kit
00 = No Mounting Option
ꢀ
.
FG52 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 10km
ꢀ
.
ꢀ
.
FG53 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 25km
ꢀ
.
ꢀ
.
FG54 = 2 x 1000LX SFP - Singlemode, 1550nm, LC, 70km
ꢀ
.
ꢀ
.
FG70 = 2 x 1000LX GBIC - Blank (no optical transceiver)
ꢀ
.
ꢀ
.
FG71 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km
ꢀ
.
FG72 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km
PS1 and PS2: Power Supply 1 and 2
ꢀ
.
FG73 = 2 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km
ꢀ
.
24 = 24VDC (9-36VDC), screw terminal block
48 = 48VDC (36-72VDC), screw terminal block
HI = 88-300VDC or 85-264VAC, screw terminal block
24P = 24VDC (9-36VDC), pluggable terminal block
48P = 48VDC (36-72VDC), pluggable terminal block
HIP = 88-300VDC or 85-264VAC, pluggable terminal block
XX = No Power Supply (PS2 Only)
ꢀ
.
S6: Gigabit Ethernet Modules for slot 6
ꢀ
.
ꢀ
.
XXXXX = Empty
ꢀ
.
ꢀ
.
1CG01 = 1 x 10/100/1000Tx RJ45
ꢀ
.
ꢀ
.
1FG01 = 1 x 1000SX - Multimode, 850nm, LC, 500m
ꢀ
.
ꢀ
.
1FG02 = 1 x 1000LX - Singlemode, 1310nm, SC connectors, 10km
ꢀ
.
ꢀ
.
1FG03 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 10km
ꢀ
.
1FG04 = 1 x 1000LX - Singlemode, 1310nm, SC connectors, 25km
S1, S2, S3, S4, S7, S8, S9 and S10:
ꢀ
.
1FG05 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 25km
Ethernet Modules for Slots 1, 2, 3, 4, 7, 8, 9 and 10
ꢀ
.
1FG50 = 1 x 1000SX SFP - Blank (no optical transceiver)
ꢀ
.
XXXX = Empty
ꢀ
.
1FG51 = 1 x 1000SX SFP - Multimode, 850nm, LC, 500m
ꢀ
.
TX01 = 2 x 10/100Tx RJ45
ꢀ
.
1FG52 = 1 x 1000LX SFP - Singlemode, 1310nm, LC,10km
ꢀ
FL01 = 2 x 10FL - Multimode, 850nm, ST
FX01 = 2 x 100FX - Multimode, 1300nm, ST
FX02 = 2 x 100FX - Multimode, 1300nm, SC
FX11 = 2 x 100FX – Multimode, 1300nm, LC
FX03 = 2 x 100FX - Multimode, 1300nm, MTRJ
FX04 = 2 x 100FX - Singlemode, 1310nm, ST, 20km
FX05 = 2 x 100FX - Singlemode, 1310nm, SC, 20km
FX06 = 2 x 100FX - Singlemode, 1310nm, LC, 20km
FX07 = 2 x 100FX - Singlemode, 1310nm, SC, 50km
FX08 = 2 x 100FX - Singlemode, 1310nm, LC, 50km
FX09 = 2 x 100FX - Singlemode, 1310nm, SC, 90km
FX10 = 2 x 100FX - Singlemode, 1310nm, LC, 90km
ꢀ
.
1FG53 = 1 x 1000LX SFP - Singlemode, 1310nm, LC, 25km
ꢀ
.
(2)
ꢀ
.
1FG54 = 1 x 1000LX SFP - Singlemode, 1550nm, LC, 70km
ꢀ
.
ꢀ
.
1FG70 = 1 x 1000LX GBIC - Blank (no optical transceiver)
ꢀ
.
ꢀ
.
1FG71 = 1 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km
ꢀ
.
ꢀ
.
1FG72 = 1 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km
ꢀ
.
(2)
ꢀ
.
1FG73 = 1 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km
ꢀ
.
NOTES:
ꢀ
.
1 Distance ratings are typical but will depend on type of cabling, number of connectors and splices.
2 These transceivers have an operating temperature range of -20 °C to +85°C.
All other transceivers have an operating temperature range of -40°C to +85°C
ꢀ
.
ꢀ
.
ꢀ
.
ꢀ
.
Example Order Codes:
RSG2100-R-RM-HI-HI-TX01-TX01-FX01-FX01-FG02-
XXXXX-FX01-FX01-FX01-FX01
19” Rack mounted, HI power supply, HI power supply,
4 10/100 RJ45 Ethernet Ports, 12 100FX (Multi Mode 1350nm
Fiber) Ethernet ports, 2 1000LX (Gigabit) Ethernet ports,
with Ethernet ports on the front
RSG2100-R-RM-24-48-TX01-TX01-XXXX-XXXX-XXXX-
XXXXX-XXXX-XXXX-XXXX-XXXX
19” Rack mounted, 24VDC power supply, 48VDC power
supply, 4 10/100 RJ45 Ethernet Ports, with Ethernet
ports on the rear
RSG2100-F-RM-48-48-TX01-TX01-FX01-FX01-XXXX-XXXXX-
XXXX-XXXX-XXXX-XXXX
19” Rack mounted, 48VDC power supply, 48VDC, 4 10/100
RJ45 Ethernet Ports, 4 100FX (Multi Mode 1310nm Fiber)
Ethernet ports, with Ethernet ports on the front
Accessories/Options
82-01-0002 - Conformal Coating
41-11-0011 - Cable support brackets
43-10-0007 - Power cable (North America three
prong connector -> beau)
RuggedSwitchTM RSG2100
9
TM
RuggedSwitch RSG2100
19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports
RuggedCom Inc.
30 Whitmore Road
Woodbridge, Ontario, Canada L4L 7Z4
Tel: (905) 856-5288 Fax: (905) 856-1995
Toll Free: (888) 264-0006
Technical Support Center: (866) 922-7975 or (954) 922-7975
© 2007 RuggedCom Inc.
RuggedSwitch is a trademark of RuggedCom Inc.
Ethernet is a trademark of the Xerox Corporation.
Patent Pending
All specifications in this document are subject to change without notice.
Rev 2-U
For additional information on our products and
RuggedSwitchTM RSG2100
10
|