REJ10J1396-0300
H8SX/1582 PLQP0120LA-A
User System Interface Cable
HS1582ECH61H User’s Manual
Renesas Microcomputer Development Environment System
H8SX Family / H8SX/1500 Series
HS1582ECH61HE
Rev.3.00
Revision Date: Sep. 08, 2008
Notes regarding these materials
1. This document is provided for reference purposes only so that Renesas customers may select the appropriate
Renesas products for their use. Renesas neither makes warranties or representations with respect to the
accuracy or completeness of the information contained in this document nor grants any license to any
intellectual property rights or any other rights of Renesas or any third party with respect to the information in
this document.
2. Renesas shall have no liability for damages or infringement of any intellectual property or other rights arising
out of the use of any information in this document, including, but not limited to, product data, diagrams, charts,
programs, algorithms, and application circuit examples.
3. You should not use the products or the technology described in this document for the purpose of military
applications such as the development of weapons of mass destruction or for the purpose of any other military
use. When exporting the products or technology described herein, you should follow the applicable export
control laws and regulations, and procedures required by such laws and regulations.
4. All information included in this document such as product data, diagrams, charts, programs, algorithms, and
application circuit examples, is current as of the date this document is issued. Such information, however, is
subject to change without any prior notice. Before purchasing or using any Renesas products listed in this
document, please confirm the latest product information with a Renesas sales office. Also, please pay regular
and careful attention to additional and different information to be disclosed by Renesas such as that disclosed
5. Renesas has used reasonable care in compiling the information included in this document, but Renesas
assumes no liability whatsoever for any damages incurred as a result of errors or omissions in the information
included in this document.
6. When using or otherwise relying on the information in this document, you should evaluate the information in
light of the total system before deciding about the applicability of such information to the intended application.
Renesas makes no representations, warranties or guaranties regarding the suitability of its products for any
particular application and specifically disclaims any liability arising out of the application and use of the
information in this document or Renesas products.
7. With the exception of products specified by Renesas as suitable for automobile applications, Renesas
products are not designed, manufactured or tested for applications or otherwise in systems the failure or
malfunction of which may cause a direct threat to human life or create a risk of human injury or which require
especially high quality and reliability such as safety systems, or equipment or systems for transportation and
traffic, healthcare, combustion control, aerospace and aeronautics, nuclear power, or undersea communication
transmission. If you are considering the use of our products for such purposes, please contact a Renesas
sales office beforehand. Renesas shall have no liability for damages arising out of the uses set forth above.
8. Notwithstanding the preceding paragraph, you should not use Renesas products for the purposes listed below:
(1) artificial life support devices or systems
(2) surgical implantations
(3) healthcare intervention (e.g., excision, administration of medication, etc.)
(4) any other purposes that pose a direct threat to human life
Renesas shall have no liability for damages arising out of the uses set forth in the above and purchasers who
elect to use Renesas products in any of the foregoing applications shall indemnify and hold harmless Renesas
Technology Corp., its affiliated companies and their officers, directors, and employees against any and all
damages arising out of such applications.
9. You should use the products described herein within the range specified by Renesas, especially with respect
to the maximum rating, operating supply voltage range, movement power voltage range, heat radiation
characteristics, installation and other product characteristics. Renesas shall have no liability for malfunctions or
damages arising out of the use of Renesas products beyond such specified ranges.
10. Although Renesas endeavors to improve the quality and reliability of its products, IC products have specific
characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use
conditions. Please be sure to implement safety measures to guard against the possibility of physical injury, and
injury or damage caused by fire in the event of the failure of a Renesas product, such as safety design for
hardware and software including but not limited to redundancy, fire control and malfunction prevention,
appropriate treatment for aging degradation or any other applicable measures. Among others, since the
evaluation of microcomputer software alone is very difficult, please evaluate the safety of the final products or
system manufactured by you.
11. In case Renesas products listed in this document are detached from the products to which the Renesas
products are attached or affixed, the risk of accident such as swallowing by infants and small children is very
high. You should implement safety measures so that Renesas products may not be easily detached from your
products. Renesas shall have no liability for damages arising out of such detachment.
12. This document may not be reproduced or duplicated, in any form, in whole or in part, without prior written
approval from Renesas.
13. Please contact a Renesas sales office if you have any questions regarding the information contained in this
document, Renesas semiconductor products, or if you have any other inquiries.
Rev. 3.00 Sep. 08, 2008 Page iii of vi
REJ10J1396-0300
Rev. 3.00 Sep. 08, 2008 Page iv of vi
REJ10J1396-0300
IMPORTANT INFORMATION
READ FIRST
• READ this user's manual before using this user system interface cable.
• KEEP the user's manual handy for future reference.
Do not attempt to use the user system interface cable until you fully understand its
mechanism.
User System Interface Cable:
Throughout this document, the term "user system interface cable" shall be defined as the
following product produced only by Renesas Technology Corp. excluding all subsidiary products.
•
User system interface cable (HS1582ECH61H)
The user system or a host computer is not included in this definition.
Purpose of the User System Interface Cable:
This user system interface cable is for connecting the emulator station and user system. This
user system interface cable must only be used for the above purpose.
Improvement Policy:
Renesas Technology Corp. (including its subsidiaries, hereafter collectively referred to as
Renesas) pursues a policy of continuing improvement in design, performance, functions, and
safety of the user system interface cable. Renesas reserves the right to change, wholly or partially,
the specifications, design, user's manual, and other documentation at any time without notice.
Target User of the User System Interface Cable:
This user system interface cable should only be used by those who have carefully read and
thoroughly understood the information and restrictions contained in the user's manual. Do not
attempt to use the user system interface cable until you fully understand its mechanism.
It is highly recommended that first-time users be instructed by users that are well versed in the
operation of the user system interface cable.
Rev. 3.00 Sep. 08, 2008 Page I of VI
REJ10J1396-0300
LIMITED WARRANTY
Renesas warrants its user system interface cables to be manufactured
in accordance with published specifications and free from defects in
material and/or workmanship. Renesas will repair or replace any
user system interface cables determined to be defective in material
and/or workmanship. User system interface cables are wearing parts
which Renesas will not repair or replace if damaged and/or worn
through use. The foregoing shall constitute the sole remedy for any
breach of Renesas’ warranty. This warranty extends only to you, the
original Purchaser. It is not transferable to anyone who subsequently
purchases the user system interface cable from you. Renesas is not
liable for any claim made by a third party or made by you for a third
party.
DISCLAIMER
RENESAS MAKES NO WARRANTIES, EITHER EXPRESS OR
IMPLIED, ORAL OR WRITTEN, EXCEPT AS PROVIDED
HEREIN, INCLUDING WITHOUT LIMITATION THEREOF,
WARRANTIES AS TO MARKETABILITY, MERCHANTABILITY,
FITNESS FOR ANY PARTICULAR PURPOSE OR USE, OR
AGAINST INFRINGEMENT OF ANY PATENT. IN NO EVENT
SHALL RENESAS BE LIABLE FOR ANY DIRECT, INCIDENTAL
OR CONSEQUENTIAL DAMAGES OF ANY NATURE, OR
LOSSES OR EXPENSES RESULTING FROM ANY DEFECTIVE
USER SYSTEM INTERFACE CABLE, THE USE OF ANY USER
SYSTEM INTERFACE CABLE, OR ITS DOCUMENTATION,
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
EXCEPT AS EXPRESSLY STATED OTHERWISE IN THIS
WARRANTY, THIS USER SYSTEM INTERFACE CABLE IS SOLD
"AS IS ", AND YOU MUST ASSUME ALL RISK FOR THE USE
AND RESULTS OBTAINED FROM THE USER SYSTEM
INTERFACE CABLE.
Rev. 3.00 Sep. 08, 2008 Page II of VI
REJ10J1396-0300
State Law:
Some states do not allow the exclusion or limitation of implied warranties or liability for
incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which may vary from
state to state.
The Warranty is Void in the Following Cases:
Renesas shall have no liability or legal responsibility for any problems caused by misuse,
abuse, misapplication, neglect, improper handling, installation, repair or modifications of the user
system interface cable without Renesas’ prior written consent or any problems caused by the user
system.
All Rights Reserved:
This user's manual and user system interface cable are copyrighted and all rights are reserved
by Renesas. No part of this user's manual, all or part, may be reproduced or duplicated in any
form, in hard-copy or machine-readable form, by any means available without Renesas’ prior
written consent.
Other Important Things to Keep in Mind:
1. Circuitry and other examples described herein are meant merely to indicate the characteristics
and performance of Renesas’ semiconductor products. Renesas assumes no responsibility for
any intellectual property claims or other problems that may result from applications based on
the examples described herein.
2. No license is granted by implication or otherwise under any patents or other rights of any third
party or Renesas.
Figures:
Some figures in this user's manual may show items different from your actual system.
Limited Anticipation of Danger:
Renesas cannot anticipate every possible circumstance that might involve a potential hazard.
The warnings in this user's manual and on the user system interface cable are therefore not all
inclusive. Therefore, you must use the user system interface cable safely at your own risk.
Rev. 3.00 Sep. 08, 2008 Page III of VI
REJ10J1396-0300
SAFETY PAGE
READ FIRST
• READ this user's manual before using this user system interface cable.
• KEEP the user's manual handy for future reference.
Do not attempt to use the user system interface cable until you fully understand its
mechanism.
DEFINITION OF SIGNAL WORDS
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.
DANGER
DANGER indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING
WARNING indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
CAUTION
CAUTION used without the safety alert symbol indicates a
potentially hazardous situation which, if not avoided, may result
in property damage.
NOTE emphasizes essential information.
Rev. 3.00 Sep. 08, 2008 Page IV of VI
REJ10J1396-0300
WARNING
Observe the precautions listed below. Failure to do so
will result in a FIRE HAZARD and will damage the user
system and the emulator product or will result in
PERSONAL INJURY. The USER PROGRAM will be
LOST.
1. Do not repair or remodel the emulator product by
yourself for electric shock prevention and quality
assurance.
2. Always switch OFF the E6000H emulator and user system
before connecting or disconnecting any CABLES or
PARTS.
3. Always before connecting any CABLES, make sure that
pin 1 on both sides are correctly aligned.
Rev. 3.00 Sep. 08, 2008 Page V of VI
REJ10J1396-0300
Rev. 3.00 Sep. 08, 2008 Page VI of VI
REJ10J1396-0300
Preface
The HS1582ECH61H is a user system interface cable that connects an H8SX/1582 E6000H
emulator (HS1527KEPH60H; hereinafter referred to as the emulator) to the IC socket for an
PLQP0120LA-A (former package: FP-120B) package for the H8SX/1582 MCU on the user system.
Contents
Section 1 Configuration...........................................................................................1
Section 2 Connection Procedures............................................................................3
2.1
Connecting User System Interface Cable to Emulator Station ............................................. 3
2.2
Connecting User System Interface Cable to User System .................................................... 5
2.2.1
2.2.2
2.2.3
2.2.4
2.2.5
Installing IC Socket............................................................................................... 5
Soldering IC Socket.............................................................................................. 6
Inserting Cable Head............................................................................................. 7
Fastening Cable Head ........................................................................................... 7
Fastening Cable Body........................................................................................... 9
2.3
2.4
2.5
Recommended Dimensions for User System Mount Pad................................................... 10
Dimensions for User System Interface Cable Head............................................................ 11
Resulting Dimensions after Connecting User System Interface Cable............................... 12
Section 3 Installing the MCU to the User System.................................................13
Section 4 Verifying Operation...............................................................................15
Section 5 Notice.....................................................................................................17
Section 1 Configuration
Section 1 Configuration
CAUTION
Use an NQPACK120SE-ND socket and an HQPACK120SE
cover (manufactured by Tokyo Eletech Corporation) for the
PLQP0120LA-A package IC socket on the user system.
Figure 1 and table 1 show the external appearance and components, respectively, of the
HS1582ECH61H user system interface cable for the PLQP0120LA-A package.
To emulator station
Cable body
Screws (M2.0 x 10 mm)
(for fastening cable head)
Screws (M2.0 x 6 mm)
Socket cover
Cable head
IC socket
User system
Figure 1 HS1582ECH61H User System Interface Cable
Rev. 3.00 Sep. 08, 2008 Page 1 of 18
REJ10J1396-0300
Section 1 Configuration
Table 1 lists the HS1582ECH61H components. Please make sure you have all of these
components when unpacking.
Table 1
HS1582ECH61H Components
No. Component
Quantity
Remarks
1
2
3
4
5
6
7
8
9
Cable body
1
1
1
1
4
4
3
1
1
Cable
Cable head
IC socket
For the PLQP0120LA-A package
Socket cover
For installing an PLQP0120LA-A packaged MCU
For fastening cable head
Screws (M2.0 x 10 mm)
Screws (M2.0 x 6 mm)
Guide pins (φ1 mm)
Screwdriver
For installing an PLQP0120LA-A packaged MCU
For determining the IC socket location
For tightening screws
Documentation
User’s manual for HS1582ECH61H (this manual)
Rev. 3.00 Sep. 08, 2008 Page 2 of 18
REJ10J1396-0300
Section 2 Connection Procedures
Section 2 Connection Procedures
2.1
Connecting User System Interface Cable to Emulator Station
WARNING
Observe the precautions listed below. Failure to do so
will result in a FIRE HAZARD and will damage the user
system and the emulator product or will result in
PERSONAL INJURY. The USER PROGRAM will be LOST.
1. Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before
connecting, make sure that pin 1 on both sides are
correctly aligned.
2. The user system interface cable dedicated to the
emulator must be used.
To connect the cable body to the emulator station, follow the instructions below.
1. Make sure the user system and emulator station are turned off.
CAUTION
When connecting or removing the user system interface
cable, apply force only in the direction suitable for
connection or removal, while making sure not to bend or
twist the cable or connectors. Otherwise, the connectors
will be damaged.
Rev. 3.00 Sep. 08, 2008 Page 3 of 18
REJ10J1396-0300
Section 2 Connection Procedures
2. After making sure the direction of the cable body connector is correct, firmly insert the cable
body connector into the emulator station socket (figure 2).
E6000H
RENESAS
HS1527KEPH60H
emulator station
Cable body connector
User system interface cable
Figure 2 Example of the HS1527KEPH60H Emulator Station
Rev. 3.00 Sep. 08, 2008 Page 4 of 18
REJ10J1396-0300
Section 2 Connection Procedures
2.2
Connecting User System Interface Cable to User System
WARNING
Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before
connecting, make sure that pin 1 on both sides are correctly
aligned. Failure to do so will result in a FIRE HAZARD and
will damage the user system and the emulator product or
will result in PERSONAL INJURY. The USER PROGRAM will
be LOST.
To connect the cable head to the user system, follow the instructions below.
2.2.1 Installing IC Socket
After checking the location of pin 1 on the IC socket fasten it to the user system before soldering.
CAUTION
After confirming the location of pin 1 on the IC socket,
apply epoxy resin adhesive to the end of the four projections
at the bottom of the IC socket, and fasten it to the user
system.
Rev. 3.00 Sep. 08, 2008 Page 5 of 18
REJ10J1396-0300
Section 2 Connection Procedures
Use the guide pins provided to determine where to install the IC socket, as shown in figure 3.
Pin 1
Guide pins
4 projections to apply
IC socket
epoxy resin adhesive to
(NQPACK120SE-ND
manufactured by
Tokyo Eletech Corporation)
Bottom view of IC socket
User system
Figure 3 Location Setting of IC Socket
2.2.2
Soldering IC Socket
After fastening, solder the IC socket for an PLQP0120LA-A package to the user system.
CAUTION
Be sure to completely solder the leads so that the solder
slops gently over the leads and forms solder fillets. (Use
slightly more solder than the MCU.)
Rev. 3.00 Sep. 08, 2008 Page 6 of 18
REJ10J1396-0300
Section 2 Connection Procedures
2.2.3
Inserting Cable Head
CAUTION
Check the location of pin 1 before inserting.
Align pin 1 on the IC socket for an PLQP0120LA-A package on the user system with pin 1 on the
user system interface cable head, and insert the user system interface cable head into the IC socket on
the user system, as shown in figure 4.
2.2.4
Fastening Cable Head
CAUTION
1. Use a screwdriver whose head matches the screw head.
2. The tightening torque must be 0.054 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw
head may break or an IC socket contact error may be
caused by a crack in the IC socket solder.
3. If the emulator does not operate correctly, cracks might
have occurred in the solder. Check conduction with
a tester and re-solder the IC socket if necessary.
Rev. 3.00 Sep. 08, 2008 Page 7 of 18
REJ10J1396-0300
Section 2 Connection Procedures
Fasten the user system interface cable head to the IC socket for an PLQP0120LA-A package on the
user system with the four screws (M2.0 x 10 mm) provided. Each screw should be tightened a little
at a time, alternating between screws on opposing corners. Take special care, such as manually
securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by
overtightening the screws or twisting the components.
Screws (M2.0 x 10 mm)
Pin 1
Cable head
IC socket
(NQPACK120SE-ND
manufactured by
Pin 1
Tokyo Eletech Corporation)
User system
Figure 4 Connecting User System Interface Cable to User System
Rev. 3.00 Sep. 08, 2008 Page 8 of 18
REJ10J1396-0300
Section 2 Connection Procedures
2.2.5
Fastening Cable Body
Connect the cable body to the cable head.
Cable body
Removing
Push the unfastening jig
Unfastening jig
Cable head
User system
Figure 5 Fastening Cable Body
Rev. 3.00 Sep. 08, 2008 Page 9 of 18
REJ10J1396-0300
Section 2 Connection Procedures
2.3
Recommended Dimensions for User System Mount Pad
Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with
an IC socket for an PLQP0120LA-A package (NQPACK120SE-ND: manufactured by Tokyo
Eletech Corporation). The dimensions in figure 6 are somewhat different from those of the actual
chip's mount pad. Also, note the user system can not be connected to the user system interface cable
with inserting the guide pins in place.
0.40 x 29 = 11.6 ± 0.05
0.40 ± 0.05
0.2 ± 0.05
3.0 - φ1.0
5.8
Unit: mm
Figure 6 Recommended Dimensions for Mount Pad
Rev. 3.00 Sep. 08, 2008 Page 10 of 18
REJ10J1396-0300
Section 2 Connection Procedures
2.4
Dimensions for User System Interface Cable Head
The dimensions for the user system interface cable head are shown in figure 7.
23.0
20.25
63.5
Unit: mm
Tolerance: ±0.5 mm
Figure 7 Dimensions for User System Interface Cable Head
Rev. 3.00 Sep. 08, 2008 Page 11 of 18
REJ10J1396-0300
Section 2 Connection Procedures
2.5
Resulting Dimensions after Connecting User System Interface Cable
The resulting dimensions, after connecting the user system interface cable head to the user system,
are shown in figure 8.
Cable head
IC socket
User system
(NQPACK120SE-ND
manufactured by
Tokyo Eletech Corporation)
Unit: mm
Tolerance: ±0.5 mm
Figure 8 Resulting Dimensions after Connecting User System Interface Cable
Rev. 3.00 Sep. 08, 2008 Page 12 of 18
REJ10J1396-0300
Section 3 Installing the MCU to the User System
Section 3 Installing the MCU to the User System
CAUTION
1. Check the location of pin 1 before inserting.
2. Use a screwdriver whose head matches the screw head.
3. The tightening torque must be 0.054 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw
head may break or an IC socket contact error may be
caused by a crack in the IC socket solder.
4. If the MCU does not operate correctly, cracks might have
occurred in the solder. Check conduction with a tester
and re-solder the IC socket if necessary.
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as shown
in figure 9. After inserting the MCU, fasten the socket cover with the provided four screws (M2.0 x
6 mm). Take special care, such as manually securing the IC socket soldered area, to prevent the IC
socket from being damaged by overtightening the screws or twisting the components.
Rev. 3.00 Sep. 08, 2008 Page 13 of 18
REJ10J1396-0300
Section 3 Installing the MCU to the User System
Screws (M2.0 x 6 mm)
Socket cover
(HQPACK120SE
manufactured by
Tokyo Eletech Corporation)
MCU
Pin 1
IC socket
(NQPACK120SE-ND
manufactured by
Tokyo Eletech Corporation)
User system
Figure 9 Installing MCU to User System
Rev. 3.00 Sep. 08, 2008 Page 14 of 18
REJ10J1396-0300
Section 4 Verifying Operation
Section 4 Verifying Operation
1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H Emulator
User's Manual (HS1650EPH60HE).
2. Verify the user system interface cable connections by checking the pin states with the CHECK
command (emulator command). If an error is detected, recheck the soldered IC socket and the
location of pin 1.
3. The emulator connected to this user system interface cable supports three kinds of clock sources
as the MCU clock: an emulator internal clock, an external clock on the user system, and a crystal
oscillator to be mounted on the EV-chip board. For details, refer to the H8SX/1650 E6000H
Emulator User's Manual (HS1650EPH60HE).
⎯ To use the emulator internal clock
Select the clock in the emulator by using the CLOCK command (emulator command).
⎯ To use the external clock on the user system
Select the external clock with the CLOCK command (emulator command). Supply the
external clock from the user system to the emulator by inputting the external clock from the
EXTAL terminal on the cable head or connecting a crystal oscillator to the EXTAL and
XTAL terminals. For details, refer to the H8SX/1520 Group Hardware Manual.
⎯ To use the crystal oscillator mounted on the EV-chip board
Install a crystal oscillator into the crystal oscillator terminals on the EV-chip board.
Figure 10 shows the oscillator circuit on the user system interface cable.
1 MΩ
HCU04
To E6000H
emulator
HCU04
270 Ω
EXTAL XTAL
Figure 10 Oscillator Circuit
Rev. 3.00 Sep. 08, 2008 Page 15 of 18
REJ10J1396-0300
Section 4 Verifying Operation
Rev. 3.00 Sep. 08, 2008 Page 16 of 18
REJ10J1396-0300
Section 5 Notice
Section 5 Notice
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable
head before inserting the cable head into the user system IC socket.
2. This user system interface cable is specifically designed for the HS1527KEPH60H emulator.
Do not use this cable with any other emulator station.
3. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on
the user system interface cable.
4. While the emulator station is connected to the user system with the user system interface cable,
force must not be applied to the cable head. Place the emulator station, user system interface
cable, and user system as shown in the example in figure 11.
Place components so that the cable body and cable head are
parallel to the user system.
Cable
Emulator's front-end unit
Cable head is parallel
to emulator station
Cable head is parallel
to user system
User system
Figure 11 User System Interface Cable Location Example
5. The P1 short connector is used for testing. Do not remove the jumper pin that is inserted in
the side of pins 1 and 2.
1
3
P4
P1
3
1
Figure 12 P1 and P4 Short Connectors
6. A level-shift circuit with AVcc0 and AVcc1 is mounted on the user system interface cable, as
shown in figure 13. At shipment, the jumper pin is inserted in the side of pins 1 and 2 of the
Rev. 3.00 Sep. 08, 2008 Page 17 of 18
REJ10J1396-0300
Section 5 Notice
P4 short connector. For details on the differences between the target MCU and the emulator,
refer to the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE). For the ranges
of input voltages of AVcc0 and AVcc1, refer to the H8SX/1520 Group Hardware Manual.
CAUTION
Insert the jumper pin in the P4 short connector so that
the higher voltage between AVcc0 and AVcc1 is selected.
Select either AVcc0 or AVcc1 when their potentials are
the same. Do not use the emulator without jumper pins.
User system interface
AVcc0
Emulator station
5 V
1.03 k
+
UVREF3
-
2 k
AVss
1
3
AVcc1
AVcc of MCU
5 V
of the emulator
station
1.03 k
P4
+
-
UVREF1
2 k
Settings of short connector:
Between pins 1 and 2: AVcc0
Between pins 2 and 3: AVcc1
AVss
Figure 13 Level-shift Circuit with AVcc0 and AVcc1
Rev. 3.00 Sep. 08, 2008 Page 18 of 18
REJ10J1396-0300
H8SX/1582 PLQP0120LA-A
User System Interface Cable
HS1582ECH61H User's Manual
Publication Date: Rev.1.00, June 15, 2004
Rev.3.00, September 8, 2008
Published by:
Sales Strategic Planning Div.
Renesas Technology Corp.
Customer Support Department
Global Strategic Communication Div.
Renesas Solutions Corp.
Edited by:
© 2008. Renesas Technology Corp., All rights reserved. Printed in Japan.
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan
RENESAS SALES OFFICES
Renesas Technology America, Inc.
450 Holger Way, San Jose, CA 95134-1368, U.S.A
Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501
Renesas Technology Europe Limited
Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.
Tel: <44> (1628) 585-100, Fax: <44> (1628) 585-900
Renesas Technology (Shanghai) Co., Ltd.
Unit 204, 205, AZIACenter, No.1233 Lujiazui Ring Rd, Pudong District, Shanghai, China 200120
Tel: <86> (21) 5877-1818, Fax: <86> (21) 6887-7858/7898
Renesas Technology Hong Kong Ltd.
7th Floor, North Tower, World Finance Centre, Harbour City, Canton Road, Tsimshatsui, Kowloon, Hong Kong
Tel: <852> 2265-6688, Fax: <852> 2377-3473
Renesas Technology Taiwan Co., Ltd.
10th Floor, No.99, Fushing North Road, Taipei, Taiwan
Tel: <886> (2) 2715-2888, Fax: <886> (2) 3518-3399
Renesas Technology Singapore Pte. Ltd.
1 Harbour Front Avenue, #06-10, Keppel Bay Tower, Singapore 098632
Tel: <65> 6213-0200, Fax: <65> 6278-8001
Renesas Technology Korea Co., Ltd.
Kukje Center Bldg. 18th Fl., 191, 2-ka, Hangang-ro, Yongsan-ku, Seoul 140-702, Korea
Tel: <82> (2) 796-3115, Fax: <82> (2) 796-2145
Renesas Technology Malaysia Sdn. Bhd
Unit 906, Block B, Menara Amcorp, Amcorp Trade Centre, No.18, Jln Persiaran Barat, 46050 Petaling Jaya, Selangor Darul Ehsan, Malaysia
Tel: <603> 7955-9390, Fax: <603> 7955-9510
Colophon 6.2
H8SX/1582 PLQP0120LA-A
User System Interface Cable
HS1582ECH61H User’s Manual
|