Gas Stoves
U38 Gas Stove
U38 Top Vent Freestanding B-Vent Gas Stove
Model
Fuel Type
U38-NG1
U38-LP1
Propane
Natural Gas
5” W.C. (1.25 kPa)
3.8” W.C. (0.94 kPa)
1.1” W.C. (0.27 kPa)
#31
Minimum Supply Pressure
12” W.C. (3.00 kPa)
11” W.C. (2.74 kPa)
2.9” W.C. (0.72 kPa)
Manifold Pressure - High
Manifold Pressure - Low
Orifice Size Altitude 0-2000ft (0-610m)
Orifice Size Altitude 2000-4500ft (610-1370m)
Orifice Size 30,000 Max BTU
#50
#33
#37
#52
Minimum Input Altitude 0-2000ft (0-610m)
Minimum Input Altitude 2000-4500ft (610-1370m)
Minimum Input Converted to 30,000 Max BTU
Maximum Input Altitude 0-2000ft (0-610m)
Maximum Input Altitude 2000-4500ft (610-1370m)
Maximum Input Converted to 30,000 Max BTU
Vent Sizing
21,000 BTU/h
19,000 BTU/h
15,000 BTU/h
40,000 BTU/h
36,000 BTU/h
30,000 BTU/h
4” B-Vent
20,000 BTU/h
15,000 BTU/h
38,000 BTU/h
30,000 BTU/h
4” B-Vent
Approved Venting Systems
Vent Systems:
Listed B-Vent, Class-A or Masonry
Chimney with approved liner (FPI
AstroCap™ Flex Vent)
K
J
L
I
C
I
A
D
B
M
N
N
E
H
M
G
Alcove clearances
Dimension
Description
U38
F
I
Side Wall to Unit
7-1/2” (190mm)
J
K
L
Back Wall to Unit
6” (155mm)
Back Wall to Vent Centerline
Side Wall to Vent Centerline
10-3/4” (273mm)
20-1/2” (521mm)
Corner Clearances
Dimension
Description
U38
A
B
C
D
E
F
Top Width
26” (660mm)
30” (762mm)
Dimension
M
Description
Wall to Unit Corner
U38
2” (50mm)
Unit Height
Top Depth (back to front face)
Top Depth
17-5/8” (448mm)
17” (432mm)
N
Wall to Vent Centerline
11” (280mm)
Minimum ceiling height is 36" (914mm) from top of unit.
Height; Base to Gas Line
Top; Front to Back
Depth; Flue-Centerline to Back
Width; Side of unit to Gas Line
3-1/2” (89mm)
17” (432mm)
Minimum clearance to vent : According to B-Vent Manufacturer
The above listed clearances are minimum distances to combustible
materials. When installing on carpet or vinyl flooring the bottom pedestal
cover plate must be installed.
G
H
3-1/2” (89mm)
10-3/4” (273mm)
June 2007 Regency Product Specifications Book
155
|