Raypak Swimming Pool Heater 302B User Guide

Hi Delta® - Type P  
Job:  
Engineer:  
Contractor:  
Prepared By:  
Model:  
Commercial Pool Heaters  
Models 302B & 402B  
Date:  
Indoor/Outdoor:  
MBTUH Input:  
Sealed Combustion Chamber  
100% Factory Fire Tested  
Efficiency: 85%  
Minimum Non-condensing Inlet Temperature: 105°F  
Thermal Shock Proof Heat Exchanger  
Limited Twenty-year Thermal Shock Warranty  
Limited Five-year Heat Exchanger Warranty  
Diagnostic Center with Fault History  
PolyTuf Powder Coated Cabinet  
No Combustible Floor Shield Required  
Fan-assisted  
Non-ferrous Bypass  
Patented Burner Security Blanket  
Heat Exchanger  
Gas Train  
Options  
Bronze Headers  
Gas Pressure Regulator  
C-6 Ignition Module, Manual Reset  
D-21 TruSeal™ Direct Vent  
F-10 Low Water Cut-Off, Remote  
Probe  
ASME Inspected and Stamped  
160 PSIG Working Pressure  
National Board Approved  
Cupro Nickel Finned Tubing  
ASME Steel Tube Sheet  
Silicone High Temp O-Rings  
125 PSIG ASME Pressure Relief Valve  
Temperature and Pressure Gauge  
Water Connections  
Left – Standard  
Right – Option A-6  
Bronze Pump, 1/3 HP, 120V, 60Hz  
Non-Ferrous Pool Bypass Assembly  
with Automatic Control  
Safety Shut-off Valve  
Firing Control Valve  
On/Off Firing  
Fuel  
I-1  
High Limit Control, Auto Reset  
Natural Gas  
Propane Gas  
Design Certified ANSI Z21.56/  
CSA 4.7  
S-1 Low Gas Pressure Switch,  
Manual  
S-2 High Gas Pressure Switch,  
Manual  
X-1 SureRack™ Kit  
X-2 SureRack Add-on  
Burner  
Ultra-low NOx:  
Less Than 30 PPM  
Regulatory Agency Requirements  
G-1 CSD-1  
Construction  
Indoor/Outdoor Construction  
Enclosed Front Controls  
Controls  
120V, 60Hz, 1Power Supply  
Venting  
120/24V 60Hz Transformer  
100% Shut-off/Lockout  
Hot Surface Ignition  
Remote Flame Sensor  
High Limit Control, Auto Reset  
On/Off Power Switch  
Manual Shut-off, Front-mounted  
Flow Switch  
Blocked Vent Pressure Switch  
Combustion Air Proving Switch  
Economaster Pump Time Delay  
Poolstat  
Vent Location  
Top – Standard  
Rear – Option D-14  
Vent Termination Cap  
Outdoor – Option D-11  
Indoor, Horizontal –  
Option D-15  
Indoor, Vertical (by others)  
Combustion Air  
In-Line Filter Kit (TruSeal  
only) – Option D-17  
Air Intake Elbow –  
Option D-16  
L
W
Catalog No.: 6000.312D  
Effective: 8-15-08  
Replaces: 2-1-08  
 

PYLE Audio Speaker PLG54 User Guide
Realistic Car Stereo System PRO 53 User Guide
Remington Electric Shaver PG 300 User Guide
Ricoh Fax Machine FAX4430L User Guide
RIDGID Soldering Gun RT 175 User Guide
Rotel Turntable RP900 User Guide
Salton Coffeemaker MEFB4B User Guide
Samsung Clothes Dryer DV306LEW User Guide
Samsung Flat Panel Television 410 Series User Guide
Samsung Laptop NP540U4E K01US User Guide