RSA Lighting Indoor Furnishings 40 DHWH User Guide

DESCRIPTION  
Catalog #  
Project  
Type  
Date  
An adjustable Multi-lamp Recessed fixture for trimless installation suitable for  
downlighting and accent applications. Utilizes THREE (3) PAR30 Metal Halide  
lamps.  
Comments  
Prepared by  
For new construction applications. Insulation must be kept 3” from all sides  
and at least 1” above the housing.  
SPECIFICATION FEATURES  
A... Housing  
branch wiring, 6 #12 90º C supply  
locking lamp adjustment. Beveled-edge  
lamp ring is secured with threadless,  
Housing, junction box & trimless  
meshplate assembly are all steel  
conductors or 60º C for end of run. The  
COMBOLIGHT®  
Next Generation  
Recessed  
fixture is also UL listed as ‘access above bayonet action. Optional retractable arm is  
construction. Perforated meshplate allows ceiling not required’.  
for trimless installation in drywall/plaster  
available for lamp pulldown and extreme  
aiming. Includes Med. base sockets.  
ceilings by allowing the ceiling’s mudding  
compound to be applied right up to the  
edge of the fixture opening. Includes  
a beveled “knife-edge” lips to ensure a  
clean edge. Can accommodate 0.50” to  
1.25” ceiling thickness. Optional Chicago  
Plenum configuration available.  
D... Electrical  
Electrical accessible through ceiling  
opening. J-Box located on the side wall  
F ... Mounting  
Butterfly Brackets accept 1/2” EMT,  
Multi-Lamp Fixture  
of the housing behind removable access C Channel, Tbar fasteners, and bar  
doors. Integral electronic metal halide  
hangers. Four tabs on housing for  
ballasts on individually removable “trays” securing to structure. Perforated flaps  
Three (3) Light  
PAR30 Metal Halide  
for easy maintenance. May also be con-  
figured for remote power.  
along housing sides for securing trimless  
insert to fixture and drywall.  
B... System Protection:  
G... Labels  
Thermal protection provided to guard  
against overheating and misuse of  
insulation over and around fixture. Vent  
E ... Lamps  
Three (3) PAR30 Metal Halide lamps mount-  
ed in adjustable double gimbals. Lamp  
cULus listed for non-type IC  
applications, suitable for use in damp  
locations.  
New Construction  
Housing  
holes in housing provide cooler operation. holders are individually removable and may  
be regressed 1” for additional cut-off. Lamp  
Ceiling Cut-Out: 6.49” x 17.87”  
Trimless  
C... Junction Box  
Junction Box is UL listed for through  
can accept up to three optical accessories  
(i.e. lens + hex louver + snoot). 45º x 45º  
27.52”  
15.01”  
7.45”  
12.01”  
23.39”  
17.07”  
5.69”  
Double  
Gimbal  
Perforated  
Meshplate  
45º x 45º  
Adjust  
5.69”  
Integral Electronic  
Metal Halide Ballasts  
Thermal  
Protector  
For use with 39W or 70W PAR30MH lamps.  
ORDERING INFORMATION  
C3  
E
N
N
Configuration  
Lamp Type / Wattage Label  
Power Supply  
Lamp Mechanism  
Trim Insert Finish  
C3 = COMBOLIGHT  
Recessed Three (3) Light  
039M30 = 39 Watt PAR30 Metal Halide  
Voltage  
G = Double Gimbal  
N = Trimless  
070M30 = 70 Watt PAR30 Metal Halide  
1
2
= 120V  
= 277V  
R
= Retractable Double Gimbal  
Housing  
Power Supply  
Trim Insert  
N = Trimless  
Housing Interior/Electrical Door/Sleeve  
N = New Construction  
E = Electronic Metal Halide  
Finish  
C = Chicago Plenum  
Ballast  
W = White  
B
S
= Black  
= Industrial Silver  
rev 022408  
Specifications and Dimensions subject to change without notice.  
RSA Lighting • 7945 Orion Ave. • Van Nuys, CA 91406 • 818-349-3030 • FAX 818-349-3031  
 

Quadra Fire Indoor Fireplace CASTILEI MBK User Guide
Raritan Computer Switch SW2 USB User Guide
Renesas Computer Hardware R0E530650CFJ30 User Guide
Roadmaster Automobile Accessories VRBT330W User Guide
Ryobi Router RT501W User Guide
Samsung Home Theater System MM DS80M User Guide
Scag Power Equipment Lawn Mower STHM 59999 User Guide
Sears Battery Charger 20071310 User Guide
Sears Sewing Machine 385 19601 User Guide
SECO LARM USA Door SK 1131 SQ User Guide